Resources - Retina

Showing 1 - 10 of 14 resources found in Retina

Reset

Balloon DCP with Ophtacath® and Ritleng®+ Intubation | Surgical Video

Vignette Balloon DCP with Ophtacath® and Ritleng®+ Intubation | Surgical Video

Balloon dacryocystoplasty (DCP) followed by silicone stent intubation enable to achieve a long-term patency of the lacrimal system.
In this case, Lionel Stork M.D., is performing a balloon DCP with FCI’s Ophtacath® Ballon Catheter and Ritleng®+ Autostable Lacrimal Intubation.
We would like to thank Lionel Stork M.D., for his contribution to this video.

ERM Peeling with End-Grasper Stiff DEX™ Forceps | Surgical Video

Vignette ERM Peeling with End-Grasper Stiff DEX™ Forceps | Surgical Video

Epiretinal membrane or macular pucker is the development of scar tissue over the central retina or macula.

In this case, a pars plana vitrectomy and an epiretinal membrane peeling is made with exclusive FCI x Katalyst Surgical End-Grasper Stiff DEX™ Forceps to remove retinal traction.

The “Stiff” technology adds rigidity to 25 Ga and 27 Ga instruments, giving optimal control and precision. Simply insert the instrument into the trocar cannula and watch as the sleeve retracts back inside the shaft, providing stiffness at the extremity of the instrument for a superior performance.

Morris Honey Badger Forceps | Surgical Video

Vignette Morris Honey Badger Forceps | Surgical Video

Morris Honey Badger forceps are ideal for heavier membranes, such as those found in macular puckers, diabetic retinopathy, PVR, trauma, and general epiretinal membrane removal.

The Honey Badger forceps can grasp EMP or PVR every time, with its small tenacious grip, used in a vertical/oblique orientation. Its exclusive design allows to dig into fibrosis, so as to make an edge, or grasp an edge. Direct line of sight to the tip is outstanding in the vertical/oblique orientation.

Alternatively, you can start in the more traditional horizontal orientation, still with an excellent view of tissue due to the small tip mass.

Three Mirror Lens | Key Features

Vignette Three Mirror Lens | Key Features

FCI’s Three Mirror Lens was designed to give high resolution visualization of the four internal zones at the slit lamp. It can be used both in the operating room and the consulting office.

The Three Mirror Lens provides a 30° central view, angulations of 59°, 67°, 75°, 0.93x image magnification and is made of PMMA.

Discover now all key features of FCI’s Three Mirror Lens!

Backflush Handpiece with T-Tube™ | Key Features

Vignette Backflush Handpiece with T-Tube™ | Key Features

FCI’s Backflush Handpiece with T-Tube™ is used to facilitate air-fluid exchanges during vitrectomy. It has a special T-Tube™ for easy insertion into the trocar cannula and protection of the black silicone tip.

Additionally, the Backflush Handpiece with T-Tube™ comes with a large reservoir for maximum reflux volume, plug for active and passive conversion, and male-male luer lock for active line attachment.

Discover now all key features of FCI’s Backflush Handpiece with T-Tube™!

Iris Retractors | Key Features

Vignette Iris Retractors | Key Features

FCI’s Iris Retractors are useful in cases of pupillary constriction, chronic miosis and other indications during cataract and retina surgeries, when eye drops are not enough to dilate the iris. They provide a simple, fast and safe way to retain the iris for maximum visibility.

Additionally, they come in flat bottom container covered with a transparent protective case to prevent the retractors from falling out during surgery.

Each set comes with 5 hooks individually packaged (upward position) and ready-to-use into the container. Simply rotate the protective case to access the hooks.

Discover now all key features of FCI’s Iris Retractors!

Chandelier | Key Features

Vignette Chandelier | Key Features

FCI’s Chandelier can be very useful for challenging vitrectomy cases requiring the use of bimanual instrumentation.

It provides 360° illumination and comes with a specifically designed silicone ring to fit the trocar cannula, to ensure stability, sealing and depth adjustment to regulate the intensity of light.

Additionally, the Chandelier includes one trocar cannula mounted on ultra sharp knife, also connected to a safety magnet to avoid unexpected drop during procedure.

Maculorhexis DEX™ Forceps | ILM Peeling

Vignette Maculorhexis DEX™ Forceps | ILM Peeling

Epiretinal membrane or macular pucker is the development of scar tissue over the central retina or macula.

In this case, Prof. Dr. Philipp Müther performs a pars plana vitrectomy and epiretinal membrane peel for macular pucker with exclusive FCI x Katalyst Surgical 23Ga Maculorhexis DEX™ Forceps.

FCI x Katalyst Surgical Vitreoretinal Accessories Product Catalog

Vignette FCI x Katalyst Surgical Vitreoretinal Accessories Product Catalog

Following the acquisition of Katalyst Surgical, Inc. in 2022, FCI is excited to announce the expansion of its vitreoretinal portfolio with advanced surgical retina products. Our newly expanded portfolio includes a wide range of vitreoretinal instrumentation, laser probes, illuminated laser probes, chandeliers, backflushes, and cannulas to provide added value to vitreoretinal surgeons.

Any Questions?

For more information about FCI offer or to get in touch with your local distributor,
please contact us. We will be in touch with you shortly.